Hospital · Healthcare

Healthcare buildings
Safety-first zero-carbon path

With medical safety as the absolute priority: establish a full carbon baseline, enforce department-level quotas, and stay audit-ready for green hospital programs—staged retrofits, real workflows, verified savings.

Positioning

Zero-carbon hospital platform
Safety · Full-scope carbon · Dept quotas · Audit-ready

With medical safety as the absolute priority: establish a full carbon baseline, enforce department-level energy quotas, and stay ready for green/low-carbon hospital programs—a safe, economical, auditable path to carbon neutrality.

2026 marks the start of the 15th Five-Year Plan and the shift to carbon emission dual control. Public hospitals must move from advocacy to accountable KPIs. Hospitals run 24/7 with HVAC often 40–60% of load and rigid clinical constraints. Solacred combines an integrated “retrofit · operate · account · report” platform with energy performance contracting and solar/storage/efficiency delivery—turning facilities into a governance lever for hospital leadership.

2026 = new plan cycle
Fresh public-sector energy-carbon KPIs—waiting is no longer an option
Carbon dual control
Shift from energy-only to total & intensity carbon control with verifiable data
Energy performance contracting
Retrofits without large upfront CAPEX; savings shared under contract
Green hospital ratings
Industry guides now expect data, retrofits & operations—not slogans
11
Functional modules
M1–M11 covering monitoring, accounting, quotas, safety, evaluation & neutrality
17+
Hospital systems
Clean OR HVAC, medical gas, dialysis, MRI, nuclear medicine, etc.
13
MEP strategies
Fine-grained energy & safety policies by clinical zone
24/7
Continuous monitoring
Multi-level drill-down, YoY/MoM, COP diagnostics & alerts
Industry pain points

Six hospital challenges · Systematically solved

Core barriers to hospital decarbonization—and how our platform addresses them end to end.

Unknown carbon baseline

Only total electricity bills—no dept/system view; hospital-specific sources stay outside accounting.

Sub-metering + full-scope carbon

Campus→building→dept→system drill-down; Scope 1/2/3 plus anesthetic gas, waste, wastewater in one ledger.

Shared energy “pot”

Departments lack cost awareness and KPIs; savings don’t stick.

Quotas + 3-level alerts + ranking

Draft→issue approval; auto recalc usage; yellow/orange/red alerts and dept performance benchmarks.

Afraid to save energy

Fear of impacting OR air changes, ICU conditions, medical gas pressure, MRI rooms.

Medical safety constraint engine

Pre-check every strategy: pass / block / sign-off; execute only after approval with full audit trail.

Missing special sources

Anesthetic gas, refrigerant leaks, medical waste, wastewater—gaps in disclosure.

Hospital-specific ledgers

Classified records; auto-calc→confirm→monthly settlement→exportable reports.

Manual compliance packs

Green hospital & public-sector filings assembled by hand—inconsistent and error-prone.

Benchmarking + application packs

Map to GB/T 51153 & T/SHWSHQ 14; evidence chain & structured exports.

Tight budget · hard KPIs · scattered ownership

Retrofits wait for capital; data mismatches hurt ratings; teams work in silos.

Contracting × platform integration

EPC answers “who pays & how to retrofit”; platform answers “how much energy & carbon, how to report”.

Core value

Eight value pillars Powering zero-carbon hospitals

Safety-first savings, full-scope carbon, dept quotas, evaluation readiness—four differentiators for proactive governance.

Safety-first efficiency

Medical safety engine—every strategy passes OR/ICU/infection redlines first

  • 安全红线库(换气次数/正压/供氧/机房温度等)
  • 策略校验:pass / blocked / need_signoff
  • 会签批准 + 执行留痕 + 应急演练台账

Full-scope carbon accounting

Energy + anesthetic gas + refrigerants + waste + wastewater + radioactive waste

  • Scope 1/2/3 分层展示
  • 自动核算与月度结算确认
  • 结构化核算报告导出

Department quotas & KPIs

Break the shared pot; support cost allocation & performance reviews

  • 医院/科室/楼栋/系统多级定额
  • 用量重算 + 三级预警
  • 告警一键生成整改工单

Dedicated system management

Clean HVAC, medical gas, CSSD, dialysis, imaging & 13 system types

  • 17+ 医院专属用能系统纳管
  • COP / 能效诊断与改造测算
  • 诊断→工单→验收闭环

Green hospital readiness

Benchmark national & industry standards for creation & renewal

  • GB/T 51153 等指标映射
  • 评分模拟与差距分析
  • 申报材料与证据链辅助

Solar, storage & green power

Roof PV, BESS, chargers & green certificates

  • 绿电占比提升、范围二减排
  • 需求响应/VPP(白名单负荷)
  • 与 EMS 策略协同

Carbon inclusion & assets

Staff green behavior, CCER/certificates & neutrality gap offset

  • 碳积分与碳普惠台账
  • 碳资产核销与抵销联动
  • 回写碳中和目标进度

AI carbon assistant

Forecast, diagnose, compliance checks & report assist (phased rollout)

  • 能耗/碳排趋势预测
  • 异常诊断与自然语言问答
  • 合规校验与报告生成辅助
Flagship differentiator

Medical safety constraint engine · Safety before savings

Unlike generic buildings, hospital efficiency can collide with clinical safety, infection control & radiation protection. We embed safety-first logic in the platform—not as an afterthought.

01

Submit strategy

Select zone & parameter (e.g. OR air changes, room temperature setpoint)

02

Redline auto-check

Compare against clean HVAC, medical gas, imaging, IT room limits

03

Verdict & routing

pass · blocked · need_signoff for human review

04

Sign-off approve/reject

Infection control / clinical / facilities review with ActionLog

05

Execute + interlock

Post-approval dispatch with executedAt & drill replay support

Medical safety constraint engine

Unlike generic buildings, hospital efficiency can collide with clinical safety, infection control & radiation protection. We embed safety-first logic in the platform—not as an afterthought.

No-touch whitelist

OR, ICU, negative pressure, MRI standby zones/parameters strongly constrained by default.

Multi-energy drills

Power loss, medical gas outage, steam loss scenarios with joint facilities/infection review.

Edge interlock

After platform approval, coordinate with local BMS/clean-air unit interlocks.

Full replay

Every check, sign-off & execution logged for audit and incident traceability.

Capability map

M1–M11 modules · Scenario platform

Zero-carbon hospital system on MeetCarbon-OS: reuses building, EMS, solar/storage/charging & carbon modules, plus hospital-only safety & carbon sources.

M1

Energy-carbon monitoring

Energy map, sub-metering, realtime monitoring, carbon intensity & alerts

多级下钻同比环比对标排名
M2

Full-scope carbon accounting

Scope 1/2/3, hospital-specific ledgers, auto-calc & monthly settlement

麻醉气体医废污水报告导出
M3

Energy quotas

Multi-level quotas, draft→issue, recalc & 3-level alerts

科室分摊绩效排名整改闭环
M4

Efficiency & O&M

COP diagnostics, retrofit ROI, work-order lifecycle & M&V

一键派单派工验收回收年限
M5

Medical safety constraints

Redlines, strategy checks, sign-offs & emergency drills

拦截/会签执行留痕禁调白名单
M6

Green power & storage

PV/BESS/chargers, green certificates & demand response

绿电占比峰谷套利VPP 白名单
M7

Green hospital evaluation

GB/T 51153 mapping, score simulation & application materials

指标映射差距分析证据链
M8

Carbon inclusion & assets

Points, CCER/certificates, retirement & neutrality offset

职工低碳资产核销进度联动
M9

AI carbon assistant

Forecast, diagnosis, compliance Q&A & report assist

趋势预测合规问答报告生成
M10

Leadership cockpit

KPI overview, trends, open alerts & work-order deep links

碳中和进度待办处置一屏决策
M11

Neutrality pathway

Baseline year, target breakdown, measure library & scenarios

路线图措施库情景模拟
Hospital-specific

Carbon others don’t count · Full Scope 1/2/3

Hospital accounting must cover clinical emission sources—or disclosure and neutrality targets will show structural gaps.

Scope 1
Direct
  • Fossil fuels
  • Anesthetic gas (desflurane/sevoflurane/N₂O)
  • Refrigerant leaks
  • Emergency diesel
Scope 2
Purchased energy
  • Grid electricity
  • Purchased steam/hot water
  • Green power/certificate offset
Scope 3
Other indirect
  • Medical waste disposal
  • Wastewater treatment
  • Supply chain & commute (phased)

Anesthetic gas

Scope 1

OR volatilization with high GWP—a major Scope 1 source

Refrigerant leaks

Scope 1

Central AC, cold storage, MRI chillers

Medical waste

Scope 3

Infectious/sharp waste ledgers & outsourced disposal emissions

Medical wastewater

Scope 3

Treatment process & residual chlorine linked estimates

Radioactive waste

Scope 3

Decay storage & outsourced disposal tracking

Purchased electricity

Scope 2

Dept allocation + green power & Scope 2 reduction

Dedicated systems

13 hospital MEP systems · Managed by clinical zone

Beyond generic buildings: clean air, medical gas, sterilization, dialysis, imaging, nuclear medicine each need distinct policies & safety bounds.

Clean OR / ICU HVAC

Air changes, positive pressure, T&H vs. efficiency boundaries

Central medical gas

O₂ pressure, manifolds & terminal monitoring

CSSD sterilization

Steam sterilization & wash energy optimization

Dialysis / RO water

Conductivity, recovery & standby energy

MRI / CT / imaging

Room cooling, standby & quench monitoring redlines

Nuclear medicine / PET

Ventilation, decay rooms & radioactive waste

Lab / fume hoods

Face velocity & safe lab ventilation

IT rooms / PUE

Temperature caps, PUE monitoring & precision AC

Utilities (boiler/laundry/kitchen)

Steam, hot water & logistics sub-metering

Medical wastewater

Treatment, residual chlorine & operating energy

Roof PV / solar carports

Coordination with clean roofs, loads & O&M access

Vertical transport / logistics

Elevators, pneumatic tube & zoning strategies

Outpatient / inpatient / diagnostics

Dept & building sub-metering and quotas

Operational closure

Not a dashboard—a workflow · Retrofit · Operate · Account · Report

Built-in state machines: approvals, dispatch, settlement & retirement are actionable, logged & replayable—supporting EPC and internal KPIs.

Safety strategy loop

Submit
Redline check
Block/sign-off
Approve & execute
Timeline replay

Efficiency work orders

Diagnosis
Create WO
Dispatch→accept
Finish & verify
Savings M&V

Quota alert loop

Draft quota
Issue approval
Recalc usage
3-level alert
Rectification WO

Carbon accounting loop

Auto-calc
Confirm draft
Monthly settle
Export report
Update account
Partnership model

Energy contracting × carbon platform · Two sides of one coin

Contracting answers “who pays & how to retrofit”; the platform answers “how much energy & carbon, how to report”. Either alone struggles under tightening KPIs.

Solacred offers investment co-build and EPC for PV, storage, HVAC/lighting retrofits, with the zero-carbon hospital platform as the digital backbone: baseline before retrofit, metering & connectivity during build, M&V and O&M after—an auditable, reviewable, application-ready chain. Leadership sets direction & safety bottom lines; specialists deliver retrofit · operate · account · report.

Zero upfront CAPEX

Under energy performance contracting, the service provider invests; savings are shared per agreement.

One data standard

Collection, accounting & reports from one platform—no mismatched filing packages.

Safety bottom line intact

Every contracted measure passes the medical safety engine—no savings at the cost of safety.

Traceable accountability

Hospital-level ownership + platform logs—retrofit, O&M, data & reporting no longer in silos.

Roadmap

Phased delivery · 15-month evolution

V1.0 baseline fast wins → V2.0 quotas & safety sign-off → V3.0 assets & neutrality—modules enabled to match budget & KPI cadence.

  • Hospital/building/dept/system archive
  • Sub-metering & energy map
  • Scope 1+2 carbon & leadership cockpit
  • Safety redline library
  • 17+ dedicated system records
合作方式

投资共建与 EPC 交付

基于七大零碳系统,Solacred 提供两种高度互补的落地路径:以资产与收益深度绑定为导向的「投资共建」,以及聚焦设计、采购、施工与并网联调的「EPC 交付」。您可根据自身的资金结构、风险偏好与项目周期,灵活选择或组合最优方案。

投资共建

Solacred 或联合投资方出资持有/参与新能源与节能类资产,与客户建立电量、电价、节能收益或碳资产等维度的分享机制。该模式极其适合期望降低前期资本支出、以场地与用能需求换取绿色电力与降本增效的用能主体。

  • ·轻资产运营,收益分成等合作结构可按场景深度定制
  • ·全面覆盖光伏、储能、充电及符合条件的节能改造项目

EPC 交付

由 Solacred 承担项目可研、工程设计、设备采购、施工安装与并网联调的一体化总包服务。该模式专为拥有自有投资预算,且对工期、质量边界与验收标准有明确要求的一次性建设需求而打造。

  • ·依托标准化工艺与供应链协同,大幅压缩建设周期与综合成本
  • ·实施数字化交底:前置预留分项计量、通信网络与平台接入条件
阅读完整合作说明

Tier-3 hospital: 100% dept compliance, improved efficiency

Department-level accounting with device & operations data; safety strategies pass redline checks & sign-off before execution—closed loop from alerts to work orders, review, and reporting.

浏览行业案例
Net-zero living system · seven pillars

Treat cities and parks as living organisms—seven subsystems from physical space to digital core. Co-investment or EPC, flexibly.

Using the seven systems as the backbone, we flexibly combine co-investment and EPC. The self-developed energy-carbon platform is the unified digital base; we layer solar, storage, charging, and efficiency measures to tailor net-zero pathways from planning and construction through long-run operations.